Victron EasySolar Inverter / Charger 12V and 24V, 1600VA

Description

Victron EasySolar Inverter Charger 12V and 24V, 1600VA

Victron EasySolar Inverter / Charger 12V and 24V, 1600VA

The all-in-one power solution! Combining both MPPT solar charger, an inverter and an AC distribution in one unit. This product is easy to install, with a minimum wiring required. This unit also features a Unique PowerAssist technology that protects the utility or generator supply from being overloaded by adding extra inverter power when needed. See below for more features and specifications.

Features:

  • PowerAssist
  • Unique solar application software
  • All-in-one solution
  • Easy installation

Specifications:

 EasySolar  EasySolar 24/3000/70-50  EasySolar 48/3000/35-50
 Inverter/charger
 Transfer switch  16 A  16 A
 Inverter
 Input voltage range 9,5 – 17 V  19 – 33 V
 Output Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1% (1)
Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1% (1)
 Cont. output power at 25 °C (3) 1600 VA / 1300 W 1600 VA / 1300 W
 Cont. output power at 40 °C 1200 W 1200 W
 Peak power 3000 W 3000 W
 Maximum efficiency  92%  94%
 Zero-load power  8 W  10 W
 Zero-load power  2 W  3 W
 Charger
 AC Input Input voltage range: 187-265 VAC
Input frequency: 45 – 65 Hz Power factor: 1
Input voltage range: 187-265 VAC
Input frequency: 45 – 65 Hz Power factor: 1
 Charge voltage ‘absorption’  14,4 V 28,8 V
 Charge voltage ‘float’ 13,8 V 27,6 V
 Storage mode 13,2 V 26,4 V
 Charge current house battery (4) 70 A  40 A
 Charge current starter battery (A)  4  4
 Battery temperature sensor  yes  yes
 Programmable relay (5)  yes  yes
 Protection (2)  a – g  a – g
 Solar Charge Controller
 Model MPPT 100/50 MPPT 100/50
 Maximum output current  50 A  50A
 Maximum PV power, 6a,b)  700 W  1400 W
 Maximum PV open circuit voltage  100 V  100 V
 Maximum efficiency  98 %  98 %
 Self-consumption  10 mA  10 mA
 Charge voltage ‘absorption’, default setting 14,4 V 28,8 V
 Charge voltage ‘float’, default setting 13,8 V 27,6 V
 Charge algorithm multi-stage adaptive  multi-stage adaptive
 Temperature compensation  -16 mV / °C  -32 mV / °C
 Protection  a – g  a – g
 Common Characteristics
 Operating temp. range  -20 to +50°C (fan assisted cooling)  -20 to +50°C (fan assisted cooling)
 Humidity (non condensing):  max 95%  max 95%
 Enclosure
 Material & Colour aluminium (blue RAL 5012) aluminium (blue RAL 5012)
 Protection category  IP 21  IP 21
 Battery-connection Battery cables of 1.5 meter Battery cables of 1.5 meter
 230 V AC-connection G-ST18i connector G-ST18i connector
 PV connection Three sets of MC4 (PV-ST01) PV connectors. Three sets of MC4 (PV-ST01) PV connectors.
 Weight 15 kg 15 kg
 Dimensions (hxwxd) 745 x 214 x 110 mm 745 x 214 x 110 mm
 Standards
 Safety EN 60335-1, EN 60335-2-29, EN 62109 EN 60335-1, EN 60335-2-29, EN 62109
 Emission / Immunity EN55014-1, EN 55014-2, EN 61000-3-3 EN55014-1, EN 55014-2, EN 61000-3-3
 Automotive Directive 2004/104/EC 2004/104/EC

1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non linear load, crest factor 3:1
4) At 25 °C ambient
5) Programmable relay which can be set for general alarm, DC
undervoltage or genset start signal function
6a) If more PV power is connected, the controller will limit input power to
700W resp. 1400W
6b) PV voltage must exceed Vbat + 5V for the