Victron EasySolar 24V and 48V, 3000VA

Description

Victron EasySolar 24V and 48V, 3000VAAll-in-one solar power solution
The EasySolar combines two MPPT solar charge controller and an inverter/charger in one enclosure. The product is easy to install, with a minimum of wiring.

Two solar charge controllers: 2x Blue Solar MPPT 100/50, 0r 2x Blue Solar MPPT 150/35
Up to six strings of PV panels can be connected to six sets of MC4 (PV-ST01) PV connectors.

The inverter/charger: MultiPlus Compact 24/3000/70-50 or 48/3000/35-50
The MPPT charge controllers and the MultiPlus inverter/charger share the DC battery connection. The batteries can be charged with solar power (2x BlueSolar MPPT) and/or with AC power (inverter/charger) from the utility grid or a Genset.

PowerAssist
Unique PowerAssist technology protects the utility or generator supply from being overloaded by adding extra inverter power when needed.

Unique solar application software
Several software programs (Assistants) are available to configure the system for various grid-interactive or stand-alone applications.

 

EasySolar EasySolar 24/3000/70-50 EasySolar 48/3000/35-50
Inverter/charger
Transfer switch 50 A
INVERTER
Input voltage range 19 – 33 V 38 – 63 V
Output Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1% (1)
Cont. output power at 25 °C (3) 3000 VA / 2500 W
Cont. output power at 40 °C 2200 W
Peak power 6000 W
Maximum efficiency 94% 95%
Zero-load power 15 W 16 W
Zero load power in search mode 5 W 5 W
CHARGER
AC Input Input voltage range: 187-265 VAC
Input frequency: 45 – 65 Hz Power factor: 1
Charge voltage ‘absorption’ 28,8 V 57,6 V
Charge voltage ‘float’ 27,6 V 55,2 V
Storage mode 26,4 V 52,8 V
Charge current house battery (4) 70 A 35 A
Charge current starter battery (A) 4
Battery temperature sensor yes
Programmable relay (5) yes
Protection (2) a – g
Solar Charge Controller
Model 2x MPPT 100/50 2x MPTT 150/35
Maximum output current 2x 50 A 2x 35 A
Maximum PV power, 6a,b) 2x 1400 W 2x 2000 W
Maximum PV open circuit voltage 100 V 150 V
Maximum efficiency 98 %
Self-consumption 10 mA
Charge voltage ‘absorption’, default setting 28,8 V 57,6 V
Charge voltage ‘float’, default setting 27,6 V 55,2 V
Charge algorithm multi-stage adaptive
Temperature compensation -16 mV / °C -32 mV / °C
Protection a – g
COMMON CHARACTERISTICS
Operating temp. range -20 to +50°C (fan assisted cooling)
Humidity (non condensing): max 95%
ENCLOSURE
Material & Colour aluminium (blue RAL 5012)
Protection category IP 21
Battery-connection Four M8 bolts (2 plus and 2 minus connections
230 V AC-connectio Screw terminals 13 mm2 (6 AWG)
PV connection Six sets of MC4 (PV-ST01) PV connectors.
Weight 21 kg
Dimensions (hxwxd) 362 x 374 x 218 mm
STANDARDS
Safety EN 60335-1, EN 60335-2-29, EN 62109, IEC 62109
Emission / Immunity EN55014-1, EN 55014-2, EN 61000-3-3
1) Can be adjusted to 60Hz and to 240V
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non linear load, crest factor 3:1
4) At 25 °C ambient
5) Programmable relay which can a. o. be set for general alarm, DC
undervoltage or genset start signal function
6a) If more PV power is connected, the solar charge controllers will limit
input power to 1400W resp. 2000W
6b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V