The new standard for small PV systems
The Sunny Boy 1.5 / 2.0 / 2.5 is the perfect inverter for customers with small PV systems. Thanks to its broad input voltage range of 80 V to 600 V, its versatility, flexibility in module compatibility and low weight for easy installation are impressive. After smooth commissioning via the integrated web interface, the Sunny Boy 1.5 / 2.0 / 2.5 is ideal for local monitoring via the device’s own wireless home network or for online monitoring with Sunny Portal or Sunny Places. Thanks to its integrated SMA Smart Connected service, this inverter offers ease and comfort for PV system operators and installers. The automatic inverter monitoring by SMA analyzes operation, reports irregularities and thus minimizes downtime.
Compact
• One-person installation due to low weight of 9.2 kg
• Compact design means minimum space requirements
Easy to Use
• 100% plug and play installation
• Free online monitoring via SunnyPlaces
• Automated service thanks to SMA Smart Connected
High Yields
• Use of surplus energy through dynamic active power limitation
• Shade management with OptiTrac Global Peak
Combinable
• Wide input voltage range
• Intelligent energy management and storage solutions can be added anytime
• Can be combined with TS4-R components for module optimization
Integrated service for ease and comfort
SMA Smart Connected* is free monitoring of an inverter via the SMA Sunny Portal. If an inverter fails, SMA proactively informs the PV system owner and the installer. This saves valuable working time and costs. With SMA Smart Connected, the installer benefits from rapid diagnoses by SMA. They can thus quickly rectify the fault and score points with the customer thanks to the additional, attractive services.
Activate on of Smart Connect
During registration of the system in the Sunny Portal, the installer activates SMA Smart Connected and benefits from automatic inverter monitoring by SMA.
Automatic inverter monitoring
SMA takes on the job of inverter monitoring with SMA Smart Connected. SMA automatically checks the individual inverters for anomalies around the clock during operation. Every customer thus benefits from SMA’s many years of experience.
Proactive communication in the event of faults
After a fault has been diagnosed and analyzed, SMA informs the installer and end customer immediately by email. Everyone is thus optimally prepared for the troubleshooting process. This minimizes downtime and saves time and money. Regular power reports also provide valuable information about the overall system.
Replacement service
If a replacement device is necessary, SMA automatically supplies a new inverter within one to three days of the fault diagnosis. The installer can contact the PV system operator of their own accord and replace the inverter.
Performance Service
The PV system operator can claim compensation from SMA if the replacement inverter is not delivered within three days.
Technical data | Sunny Boy 1.5 | Sunny Boy 2.0 |
Sunny Boy 2.5
|
---|---|---|---|
Input (DC) | |||
Max. generator power | 3000 Wp | 4000 Wp | 5000 Wp |
Max. input voltage | 600 V | ||
MPP voltage range | 160 V to 500 V | 210 V to 500 V |
260 V to 500 V
|
Rated input voltage | 360 V | ||
Min. input voltage / initial input voltage | 50 V / 80 V | ||
Max. input current input A/input B | 10 A | ||
Max. input current per string input A/input B | 18 A | ||
Number of independent MPP inputs/strings per MPP input | 1 / 1 | ||
Output (AC) | |||
Rated power (at 230 V, 50 Hz) | 1500 W | 2000 W | 2500 W |
Max. apparent power AC | 1500 VA | 2000 VA | 2500 VA |
Nominal AC voltage | 220 V / 230 V / 240 V | ||
Nominal AC voltage / range | 180 V to 280 V | ||
AC grid frequency / range | 50 Hz, 60 Hz / −5 Hz to +5 Hz | ||
Rated power frequency / rated grid voltage | 50 Hz / 230 V | ||
Max. output current | 7 A | 9 A | 11 A |
Power factor at rated power | 1 | ||
Adjustable displacement power factor | 0.8 overexcited to 0.8 underexcited | ||
Feed-in phases / connection phases | 1 / 1 | ||
Efficiency | |||
Max. efficiency / European Efficiency | 97.2 % / 96.1 % | 97.2 % / 96.4 % |
97.2 % / 96.7 %
|
Protective devices | |||
Input-side disconnection point | ● | ||
Ground fault monitoring / grid monitoring | ● / ● | ||
DC reverse polarity protection / AC short circuit current capability / galvanically isolated | ● / ● / — | ||
All-pole-sensitive residual-current monitoring unit | ● | ||
Protection class (as per IEC 62103) / overvoltage category (according to IEC 60664-1) |
I / III | ||
Reverse current protection | Not required | ||
General data | |||
Dimensions (W / H / D) | 460 / 357 / 122 mm (18.1 / 14.1 / 4.8 inches) | ||
Weight | 9.2 kg (20.3 lbs) | ||
Operating temperature range | −40 °C to +60 °C (−40 °F to +140 °F) | ||
Noise emission, typical | < 25 dB | ||
Self-consumption (at night) | 2.0 W | ||
Topology | Transformerless | ||
Cooling method | Convection | ||
Degree of protection (as per IEC 60529) | IP65 | ||
Climatic category (as per IEC 60721-3-4) | 4K4H | ||
Max. permissible value for relative humidity (non-condensing) | 100% | ||
Features | |||
DC connection / AC connection | SUNCLIX / AC connector | ||
Display via smartphone, tablet, laptop | ● | ||
Interfaces: WLAN, Speedwire / Webconnect | ● / ● | ||
Communication protocols | Modbus (SMA, Sunspec), Webconnect | ||
Warranty: 5 / 10 / 15 / 20 years | ● / ○ / ○ / ○ | ||
Certificates and approvals (more available upon request) | AS4777, C10/11, CE, CEI0-21, DIN EN 62109-1/IEC 62109-1, DIN EN 62109-2/IEC 62109-2, EN50438, G83/2, IEC61727, IEC62116, NBR16149, NEN-EN50438, NRS097-2-1, VDE-AR-N4105, VDE 0126-1-1, VFR2014 |
||
Certificates and approvals (planned) | IEC 61727, NRS 097-2-1 | ||
Country availability of SMA Smart Connected | AU, AT, BE, CH, DE, ES, FR, IT, LU, NL, UK | ||
Type designation | SB 1.5-1VL-40 | SB2.0-1VL-40 | SB2.5-1VL-40 |
Basic system functions
• Easy commissioning via integrated WLAN and Speedwire interface
• Maximum transparency thanks to visualization in Sunny Portal/Sunny Places
• Safe investment through SMA Smart Connected
• Modbus as an interface for third-party providers
Expanded system functions
• Basic system functions
• Reduction in purchased electricity and increase in self-consumption through use of stored solar energy
• Maximum energy use thanks to forecast-based charging
• Increased self-consumption thanks to intelligent load control
• Maximum system yield through Smart module technology
With SMA Energy Meter
• Maximum system usage through the dynamic limiting of feed-in to the grid between0% and 100%
• Visualization of energy consumption