Description
With power classes from 3.0 to 8.2 kW, the Fronius Primo rounds off the SnapINverter inverter generation perfectly. The single-phase, transformerless device is the ideal inverter for private households. With the innovative SuperFlex design, maximum flexibility in system design is achieved, while the SnapINverter mounting system makes installation and maintenance as easy as possible. The standard integrated communication package with WLAN, energy management, numerous interfaces and much more makes the Fronius Primo into a communicative
Technical Data FRONIUS PRIMO (3.0-1, 3.5-1, 3.6-1, 4.0-1, 4.6-1)
INPUT DATA | PRIMO 3.0-1 | PRIMO 3.5-1 | PRIMO 3.6-1 | PRIMO 4.0-1 | PRIMO 4.6-1 |
---|---|---|---|---|---|
Number of MPP trackers | 2 | ||||
Max. Input current | 12,0 A / 12,0 A | ||||
Max. Short circuit current module field | 18,0 A / 18,0 A | ||||
DC input voltage range | 80 – 1000 V | ||||
Feed-in starting voltage | 80 V | ||||
Usable MPP voltage range | 80 – 800 V | ||||
Number of DC connections | 2 + 2 | ||||
Max. PV generator output | 4,5 kWpeak | 5,3 kWpeak | 5,5 kWpeak | 6,0 kWpeak | 6,9 kWpeak |
Output data | PRIMO 3.0-1 | PRIMO 3.5-1 | PRIMO 3.6-1 | PRIMO 4.0-1 | PRIMO 4.6-1 |
AC rated power | 3.000 W | 3.500 W | 3.680 W | 4.000 W | 4.600 W |
Max. output power | 3.000 VA | 3.500 VA | 3.680 VA | 4.000 VA | 4.600 VA |
AC output current (Iac nom) | 13,0 A | 15,2 A | 16,0 A | 17,4 A | 20,0 A |
Mains connection (voltage range) | 1 ~ NPE 220 V / 230 V (180 V – 270 V) | ||||
Frequency (frequency range) | 50 Hz / 60 Hz (45 – 65 Hz) | ||||
Distortion factor | < 5 % | ||||
Power factor | 0,85 – 1 ind. / cap. | ||||
GENERAL DATA | PRIMO 3.0-1 | PRIMO 3.5-1 | PRIMO 3.6-1 | PRIMO 4.0-1 | PRIMO 4.6-1 |
Dimensions (height x width x depth) | 645 x 431 x 204 mm | ||||
Weight | 21,5 kg | ||||
Protection class | IP 65 | ||||
Protection class | 1 | ||||
Overvoltage category | 2 / 3 | ||||
Night consumption | < 1 W | ||||
Inverter concept | Trafolos | ||||
Cooling | Controlled air cooling | ||||
Assembly | Indoor and outdoor installation | ||||
Ambient temperature range | -40 – +55 °C | ||||
Permissible air humidity | 0 – 100 % | ||||
Max. Height above sea level | 4.000 m | ||||
Connection Technology DC | DC 4x DC+ and 4x DC- Screw terminals 2.5 – 16 mm². | ||||
Connection Technology AC | 3 pole AC screw terminals 2.5 – 16 mm² | ||||
Certificates and compliance with standards | DIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 4777-2, AS 4777-3, G83/2, G59/3, CEI 0-21, VDE AR N 4105 |
||||
EFFECTIVENESS | PRIMO 3.0-1 | PRIMO 3.5-1 | PRIMO 3.6-1 | PRIMO 4.0-1 | PRIMO 4.6-1 |
Max. efficiency | 98,0 % | 98,0 % | 98,0 % | 98,1 % | 98,1 % |
European efficiency (ηEU) | 96,1 % | 96,8 % | 96,8 % | 97,0 % | 97,0 % |
MPP adjustment efficiency | > 99,9 % | ||||
PROTECTIVE DEVICES | PRIMO 3.0-1 | PRIMO 3.5-1 | PRIMO 3.6-1 | PRIMO 4.0-1 | PRIMO 4.6-1 |
DC insulation measurement | Yes | ||||
Overload behaviour | Operating point shift, power limitation | ||||
DC disconnector | Yes | ||||
Reverse polarity protection | Yes | ||||
RCMU | Yes | ||||
MAKE CUTS | PRIMO 3.0-1 | PRIMO 3.5-1 | PRIMO 3.6-1 | PRIMO 4.0-1 | PRIMO 4.6-1 |
WLAN / Ethernet LAN | Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) | ||||
6 inputs and 4 digital inputs/outputs | Connection to ripple control receiver | ||||
USB (Type A socket) 2) | Data logging, inverter update via USB stick | ||||
2x RS422 (RJ45 socket) 2) | Fronius Solar Net | ||||
Message output 2) | Energy management (potential-free relay output) | ||||
Data logger and web server | Integrated | ||||
External input 2) | Connection S0 counter / evaluation overvoltage protection | ||||
RS485 | Modbus RTU SunSpec or meter connection |
Technical Data FRONIUS PRIMO (5.0-1, 5.0-1 OFF, 6.0-1, 8.2-1)
INPUT DATA | PRIMO 5.0-1 | PRIMO 5.0-1 AUS | PRIMO 6.0-1 | PRIMO 8.2-1 |
---|---|---|---|---|
Number of MPP trackers | 2 | |||
Max. Input current | 12,0 A / 12,0 A | 18,0 A / 18,0 A | ||
Max. Short circuit current module field | 18,0 A / 18,0 A | 27,0 A / 27,0 A | ||
DC input voltage range | 80 – 1000 V | |||
Feed-in starting voltage | 80 V | |||
Usable MPP voltage range | 80 – 800 V | |||
Number of DC connections | 2 + 2 | |||
Max. PV generator output | 7,5 kWpeak | 7,5 kWpeak | 9,0 kWpeak | 12,3 kWpeak |
OUTPUT PRIMO | PRIMO 5.0-1 | PRIMO 5.0-1 AUS | PRIMO 6.0-1 | PRIMO 8.2-1 |
AC rated power | 5.000 W | 4.600 W | 6.000 W | 8.200 W |
Max. output power | 5.000 VA | 5.000 VA | 6.000 VA | 8.200 VA |
AC output current (Iac nom) | 21,7 A | 21,7 A | 26,1 A | 35,7 A |
Mains connection (voltage range) | 1 ~ NPE 220 V / 230 V (180 V – 270 V) | |||
Frequency (frequency range) | 50 Hz / 60 Hz (45 – 65 Hz) | |||
Distortion factor | < 5 % | |||
Power factor (cos φac,r) | 0,85 – 1 ind. / cap. | |||
GENERAL DATA | PRIMO 5.0-1 | PRIMO 5.0-1 AUS | PRIMO 6.0-1 | PRIMO 8.2-1 |
Dimensions (height x width x depth | 645 x 431 x 204 mm | |||
Weight | 21,5 kg | |||
Protection class | IP 65 | |||
Protection class | 1 | |||
Overvoltage category (DC / AC ) 1) | 2 / 3 | |||
Night consumption | < 1 W | |||
Inverter concept | Trafolos | |||
Cooling Controlled | Air Cooling | |||
Assembly | Indoor and outdoor installation | |||
Ambient temperature range | -40 – +55 °C | |||
Permissible air humidity | 0 – 100 % | |||
Max. Height above sea level | 4.000 m | |||
Connection technology DC | 4x DC+ and 4x DC- screw terminals 2.5 – 16 mm². | |||
Connection technology AC | 3 pole AC screw terminals 2.5 – 16 mm² | |||
Certificates and compliance with standards | DIN V VDE 0126-1-1/A1, IEC 62109-1/-2, IEC 62116, IEC 61727, AS 4777-2, AS 4777-3, G83/2, G59/3, CEI 0-21, VDE AR N 4105 2) |
|||
EFFICIENCY PRIMO | PRIMO 5.0-1 | PRIMO 5.0-1 AUS | PRIMO 6.0-1 | PRIMO 8.2-1 |
Max. efficiency | 98,1 % | 98,1 % | 98,1 % | 98,1 % |
European efficiency (ηEU) | 97,1 % | 97,1 % | 97,3 % | 97,5 % |
MPP adjustment efficiency | ||||
PROTECTIVE DEVICES | PRIMO 5.0-1 | PRIMO 5.0-1 AUS | PRIMO 6.0-1 | PRIMO 8.2-1 |
DC insulation measurement | Yes | |||
Overload behaviour | Operating point shift, power limitation | |||
DC disconnector | Yes | |||
Reverse polarity protection | Yes | |||
RCMU | ||||
MAKE CUTS | PRIMO 5.0-1 | PRIMO 5.0-1 AUS | PRIMO 6.0-1 | PRIMO 8.2-1 |
WLAN / Ethernet LAN | ronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON) | |||
6 inputs and 4 digital inputs/outputs | Connection to ripple control receiver | |||
USB (Type A socket) 1) | Data logging, inverter update via USB stick | |||
2x RS422 (RJ45 socket) 1) | Fronius Solar Net | |||
Message output 1) | Energy management (potential-free relay output | |||
Data logger and web server | Integrated | |||
External input 1) | Connection S0 counter / evaluation overvoltage protection | |||
RS485 | Modbus RTU SunSpec or meter connection |