Victron MultiPlus inverter / charger

Description

Victron MultiPlus inverterVictron MultiPlus inverter / charger

In an event of a power failure MultiPlus takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. This inverter is perfect for office use. Contact us today for a quote.

Features:

  • Two AC Outputs
  • Virtually unlimited power thanks to parallel operation
  • Three phase capability
  • PowerControl – Dealing with limited generator, shore-side or grid power
  • PowerAssist – Boosting shore or generator power
  • Solar energy: AC power available even during a grid failure
  • Easy System configuring

Specifications:

MultiPlus: 12 Volt / 24 Volt / 48 Volt C 12/800/35
C 24/ 800/16
C 12/1200/50
C 24/1200/25
C 12/1600/70
C 24/1600/40
C 12/2000/80
C 24/2000/50
12/3000/120
24/3000/70
48/3000/35
24/5000/120
48/5000/70
 PowerControl / PowerAssist  Yes / Yes Yes / Yes  Yes / Yes  Yes / Yes  Yes / Yes Yes / Yes
 Transfer switch  16  16  16  30 16 or 50 100
 Parallel and 3-phase operation  Yes  Yes Yes Yes  Yes  Yes
 Inverter
 Input voltage range (V DC) 9,5 – 17 V 19 – 33 V 38 – 66 V 9,5 – 17 V 19 – 33 V 38 – 66 V 9,5 – 17 V 19 – 33 V 38 – 66 V 9,5 – 17 V 19 – 33 V 38 – 66 V  9,5 – 17 V 19 – 33 V 38 – 66 V  9,5 – 17 V 19 – 33 V 38 – 66 V
 Output (1) Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1) Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1) Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1) Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1)  Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1)  Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1)
 Cont. output power at 25 °C (VA) (3) 800 1200 1600 2000  3000  5000
 Cont. output power at 25 °C (W) 700 1000 1300 1600  2500  4500
 Cont. output power at 40 °C (W)  650 900  1200 1450  2200  4000
 Peak power (W) 1600 2400 3000 4000  6000  10.000
 Maximum efficiency (%) 92 / 94 93 / 94 93 / 94 93 / 94  93 / 94 / 95  94 / 95
 Zero-load power (W) 8 / 10 8 / 10 8 / 10 9 / 11  15 / 15 / 16  25 / 25
 Zero load power in AES mode (W) 5 / 8 5 / 8 5 / 8 7 / 9  10 / 10 / 12  20 / 20
 Zero load power in Search mode (W) 2 / 3 2 / 3 2 / 3 3 / 4  4 / 5 / 5  5 / 6
 Charger
 AC Input  Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1  Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1  Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1  Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1  Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1  Input voltage range: 187-265 VAC Input frequency: 45 – 65 Hz Power factor: 1
 Charge voltage ‘absorption’ (V DC) 14,4 / 28,8 / 57,6 14,4 / 28,8 / 57,6 14,4 / 28,8 / 57,6 14,4 / 28,8 / 57,6  14,4 / 28,8 / 57,6  14,4 / 28,8 / 57,6
 Charge voltage ‘float’ (V DC) 13,8 / 27,6 / 55,2 13,8 / 27,6 / 55,2 13,8 / 27,6 / 55,2 13,8 / 27,6 / 55,2  13,8 / 27,6 / 55,2  13,8 / 27,6 / 55,2
 Storage mode (V DC) 35 / 16 50 / 25 70 / 40 70 / 40  120 / 70 / 35  120 / 70
 Charge current house battery (A) (4)  120 / 70  220 / 120 / 70  200 / 110  140
 Charge current starter battery (A)  4 (12V and 24V models only)  4 (12V and 24V models only)  4 (12V and 24V models only)  4 (12V and 24V models only)  4 (12V and 24V models only)  4 (12V and 24V models only)
 Battery temperature sensor  Yes  Yes  Yes  Yes  Yes  Yes
 General
 Auxiliary output (A) (5) n. a.  n. a. n. a. n. a. Yes (16A)  Yes (25A)
 Programmable relay (6) Yes Yes Yes Yes  Yes  Yes
 Protection (2)  a-g a-g  a-g  a-g  a-g  a-g
 VE.Bus communication port  For parallel and three phase operation, remote monitoring and system integration  For parallel and three phase operation, remote monitoring and system integration  For parallel and three phase operation, remote monitoring and system integration  For parallel and three phase operation, remote monitoring and system integration  For parallel and three phase operation, remote monitoring and system integration  For parallel and three phase operation, remote monitoring and system integration
 General purpose com. port (7) n. a. n. a. n. a. n. a.  Yes (8)  Yes
 Remote on-off  yes  yes  yes  yes   yes   yes
 Common Characteristics Operating temp. range: -40 to +50°C (fan assisted cooling) Humidity (non condensing): max 95% Operating temp. range: -40 to +50°C (fan assisted cooling) Humidity (non condensing): max 95% Operating temp. range: -40 to +50°C (fan assisted cooling) Humidity (non condensing): max 95% Operating temp. range: -40 to +50°C (fan assisted cooling) Humidity (non condensing): max 95%  Operating temp. range: -40 to +50°C (fan assisted cooling) Humidity (non condensing): max 95%  Operating temp. range: -40 to +50°C (fan assisted cooling) Humidity (non condensing): max 95%
 Enclosure
 Common Characteristics Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21 Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21  Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21  Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21  Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21  Material & Colour: aluminium (blue RAL 5012) Protection category: IP 21
 Battery-connection Battery cables of 1.5 meter Battery cables of 1.5 meter Battery cables of 1.5 meter  M8 bolts  Four M8 bolts (2 plus and 2 minus connections)  Four M8 bolts (2 plus and 2 minus connections)
 230 V AC-connection G-ST18i connector G-ST18i connector G-ST18i connector Spring-clamp  Screw terminals 13 mm2 (6 AWG)  Screw terminals 13 mm2 (6 AWG)
 Weight (kg) 10 10 10 12  18  30
 Dimensions (hxwxd in mm) 375x214x110 375x214x110 375x214x110 520x255x125  362x258x218  444x328x240
 Standards
 Safety EN 60335-1, EN 60335-2-29 EN 60335-1, EN 60335-2-29 EN 60335-1, EN 60335-2-29 EN 60335-1, EN 60335-2-29  EN 60335-1, EN 60335-2-29  EN 60335-1, EN 60335-2-29
 Emission, Immunity EN55014-1, EN 55014-2, EN 61000-3-3 EN55014-1, EN 55014-2, EN 61000-3-3 EN55014-1, EN 55014-2, EN 61000-3-3 EN55014-1, EN 55014-2, EN 61000-3-3  EN55014-1, EN 55014-2, EN 61000-3-3  EN55014-1, EN 55014-2, EN 61000-3-3
 Emission, Immunity 2004/104/EC 2004/104/EC 2004/104/EC 2004/104/EC 2004/104/EC 2004/104/EC

Other safety features include:

1) Can be adjusted to 60 HZ; 120 V 60 Hz on request
2) Protection key:
a) output short circuit
b) overload
c) battery voltage too high
d) battery voltage too low
e) temperature too high
f) 230 VAC on inverter output
g) input voltage ripple too high
3) Non linear load, crest factor 3:1
4) At 25 °C ambient
5) Switches off when no external AC source available
6) Programmable relay that can a. o. be set for general alarm,
DC undervoltage or genset start/stop function
AC rating: 230V/4A
DC rating: 4A up to 35VDC, 1A up to 60VDC
7) A. o. to communicate with a Lithium Ion battery BMS
8) Models with 16A transfer switch only (see Quattro for 50A transfer switch)