Victron BlueSolar charge controller MPPT 75/10, 75/15 & MPPT 100/15

victron logo

Victron BlueSolar charge controller MPPT 75/10, 75/15 & MPPT 100/15

Features:

Specifications:

 BlueSolar charge controller  MPPT 75/10  MPPT 75/15  MPPT 100/15
 Battery voltage  12/24 V Auto Select  12/24 V Auto Select  12/24 V Auto Select
 Rated charge current  10 A  15 A  15 A
 Maximum PV power, 12V 1a,b)  135 W  200 W  200 W
 Maximum PV power, 24V 1a,b)  270 W  400 W  400 W
 Automatic load disconnect  Yes, maximum load 15 A  Yes, maximum load 15 A  Yes, maximum load 15 A
 Maximum PV open circuit voltage  75 V  75 V  100 V
 Peak efficiency  98 %  98 %  98 %
 Self consumption  10 mA  10 mA  10 mA
 Charge voltage ‘absorption’  14,4 V / 28,8 V (adjustable)  14,4 V / 28,8 V (adjustable)  14,4 V / 28,8 V (adjustable)
 Charge voltage ‘float’  13,8 V / 27,6 V (adjustable)  13,8 V / 27,6 V (adjustable)  13,8 V / 27,6 V (adjustable)
 Charge algorithm  multi-stage adaptive  multi-stage adaptive  multi-stage adaptive
 Temperature compensation  -16 mV / °C resp. -32 mV / °C  -16 mV / °C resp. -32 mV / °C  -16 mV / °C resp. -32 mV / °C
 Continuous/peak load current  15A / 50A  15A / 50A  15A / 50A
 Low voltage load disconnect  11,1 V / 22,2 V or 11,8 V / 23,6 V
or BatteryLife algorithm
 11,1 V / 22,2 V or 11,8 V / 23,6 V
or BatteryLife algorithm
 11,1 V / 22,2 V or 11,8 V / 23,6 V
or BatteryLife algorithm
 Low voltage load reconnect  13,1 V / 26,2 V or 14 V / 28 V
or BatteryLife algorithm
 13,1 V / 26,2 V or 14 V / 28 V
or BatteryLife algorithm
 13,1 V / 26,2 V or 14 V / 28 V
or BatteryLife algorithm
 Protection  Battery reverse polarity (fuse)
Output short circuit / Over temperature
 Battery reverse polarity (fuse)
Output short circuit / Over temperature
 Battery reverse polarity (fuse)
Output short circuit / Over temperature
 Operating temperature  -30 to +60°C (full rated output up to 40°C)  -30 to +60°C (full rated output up to 40°C)  -30 to +60°C (full rated output up to 40°C)
 Humidity  95 %, non-condensing  95 %, non-condensing  95 %, non-condensing
 Data communication port  VE.Direct
See the data communication white paper on our website
 VE.Direct
See the data communication white paper on our website
 VE.Direct
See the data communication white paper on our website
 Enclosure
 Colour  Blue (RAL 5012)  Blue (RAL 5012)  Blue (RAL 5012)
 Power terminals  6 mm² / AWG10  6 mm² / AWG10  6 mm² / AWG10
 Protection category  IP22 (connection area)  IP22 (connection area)  IP22 (connection area)
 Weight  0,5 kg  0,5 kg  0,5 kg
 Dimensions (h x w x d)  100 x 113 x 40 mm
STANDARDS
 100 x 113 x 40 mm
STANDARDS
 100 x 113 x 40 mm
STANDARDS
Standards
 Safety  EN/IEC 62109  EN/IEC 62109  EN/IEC 62109

1a) If more PV power is connected, the controller will limit input power to the stated maximum.
1b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V